Automated Sensors

Round tube type proximity switch
- Standard configuration includes three protection circuits
- Surge protection, current short circuit protection, reverse polarity protection
- The motion indicator lights are clearly visible from multiple angles.
- Made of brass plated with nickel, it has strong anti-interference capabilities.
- Outstanding impact and vibration resistance
- Solid interior, filled with full epoxy resin, waterproof, oil-proof, and heat-resistant.
- Stable transmission, robust and durable, tangle-free
▶ Main parameters - M3/M4
| Detecting objects | Magnetic metals |
|---|---|
| Difference distance | less than 10% of the detection distance |
| power supply voltage | DC12-24V ripple (pp) below 10% (DC10-30V) |
| Leakage current | 0.03mA or less |
| Action Form | NO: Normally Open, NC: Normally Closed |
| Control output | Load current below 100mA (residual constant voltage below 2V) |
| Display lamp | Action indicator light (red) |
| Protection circuit | Surge protection circuit, short circuit protection, reverse polarity protection |
| Ambient temperature | Operating temperature: -25 to 70℃ (no freezing, no condensation) |
| Ambient humidity | During operation and storage: 35-95% RH (non-condensing) |
| The effect of temperature | Temperature range -25-70℃, with a detection distance change within ±10% for every 20℃ change. |
| Effect of voltage | When the rated power supply voltage fluctuates within ±15%, the detection distance changes within ±1%. |
| Insulation resistance | 50MΩ or higher (DC 500 megohm meter) between the charging section and the casing |
| Withstand voltage | AC1000V 50/60Hz 1min charging unit and casing |
| Vibration resistance | 10~55Hz, amplitude 1.5mm, 2h in each of the X, Y, and Z directions. |
| Impact resistance | 500m/SX, Y, Z 10 times each |
| Connection method | Lead-out type (standard lead wire length 2m), special (PUR customizable) drag chain cable |
| Shell material | Nickel-plated copper material |
| Protection level | Ip67 |
▶ Product Specifications - M3/M4
| kinds | M3 Qi Ping | M4 Qi Ping | M4 Qi Ping | M4 Qi Ping |
|---|---|---|---|---|
| model | HT-φ0301-E1 (Normally Open) | HT-φ0401-E1 (Normally Open) | HT-φ041.5-E1 (Normally Open) | HT-0401-E1 (Normally Open) |
| model | HT-φ0301-E2 (Normally Closed) | HT-φ0401-E2 (Normally Closed) | HT-φ041.5-E2 (Normally Closed) | HT-0401-E2 (Normally Closed) |
| model | HT-φ0301-P1 (Normally Open) | HT-φ0401-P1 (Normally Open) | HT-φ041.5-P1 (Normally Open) | HT-0401-P1 (Normally Open) |
| model | HT-φ0301-P2 (Normally Closed) | HT-φ0401-P2 (Normally Closed) | HT-φ041.5-P2 (Normally Closed) | HT-0401-P2 (Normally Closed) |
| Detection distance | 1mm±10% | 1mm±10% | 1.5mm±10% | 1mm±10% |
| Standard test object (iron) | 3x3x1mm | 4x4x1mm | 4x4x1mm | 4x4x1mm |
| Set distance | 0-0.8mm | 0-0.8mm | 0-1.2mm | 0-0.8mm |
| Response frequency | 1200HZ | 1200HZ | 1200HZ | 1200HZ |
| wire diameter | 2.8mm | 2.8mm | 2.8mm | 2.8mm |
▶ Main parameters - M5/M8
| Detecting objects | Magnetic metals |
|---|---|
| Difference distance | less than 10% of the detection distance |
| power supply voltage | DC12-24V ripple (pp) below 10% (DC10-30V) |
| Leakage current | 0.03mA or less |
| Action Form | NO: Normally Open, NC: Normally Closed |
| Control output | Load current below 200mA (residual constant voltage below 1V) |
| Display lamp | Action indicator light (red) |
| Protection circuit | Surge protection circuit, short circuit protection, reverse polarity protection |
| Ambient temperature | Operating temperature: -25 to 70℃ (no freezing, no condensation) |
| Ambient humidity | During operation and storage: 35-95% RH (non-condensing) |
| The effect of temperature | Temperature range -25-70℃, with a detection distance change within ±10% for every 20℃ change. |
| Effect of voltage | When the rated power supply voltage fluctuates within ±15%, the detection distance changes within ±1%. |
| Insulation resistance | 50MΩ or higher (DC 500 megohm meter) between the charging section and the casing |
| Withstand voltage | AC1000V 50/60Hz 1min charging unit and casing |
| Vibration resistance | 10~55Hz, amplitude 1.5mm, 2h in each of the X, Y, and Z directions. |
| Impact resistance | 500m/SX, Y, Z 10 times each |
| Connection method | Lead-out type (standard lead wire length 2m), special (PUR customizable) drag chain cable |
| Shell material | Nickel-plated copper material |
| Protection level | Ip67 |
▶ Product Specifications - M5/M8
| kinds | M5 Qi Ping | M5 Qi Ping | M8 Qi Ping | M8⾮Qiping |
|---|---|---|---|---|
| model | HT-0501-E1 (Normally Open) | HT-051.5-E1 (Normally Open) | HT-0801-E1 (Normally Open) | HX-0802-E1 (Normally Open) |
| model | HT-0501-E2 (Normally Closed) | HT-051.5-E2 (Normally Closed) | HT-0801-E2 (Normally Closed) | HX-0802-E2 (Normally Closed) |
| model | HT-0501-P1 (Normally Open) | HT-051.5-P1 (Normally Open) | HT-0801-P1 (Normally Open) | HX-0802-P1 (Normally Open) |
| model | HT-0501-P2 (Normally Closed) | HT-051.5-P2 (Normally Closed) | HT-0801-P2 (Normally Closed) | HX-0802-P2 (Normally Closed) |
| Detection distance | 1mm±10% | 1.5mm±10% | 1mm±10% | 2mm±10% |
| Standard test object (iron) | 5x5x1mm | 5x5x1mm | 8x8x1mm | 8x8x1mm |
| Set distance | 0-0.8mm | 0-1.2mm | 0-0.8mm | 0-1.6mm |
| Response frequency | 1200HZ | 1200HZ | 1200HZ | 1000HZ |
| wire diameter | 2.8mm | 2.8mm | 3.8mm | 3.8mm |
▶ Main parameters - M12/M18
| Detecting objects | Magnetic metals |
|---|---|
| Difference distance | less than 10% of the detection distance |
| power supply voltage | DC12-24V ripple (pp) below 10% (DC10-30V) |
| Leakage current | 0.03mA or less |
| Action Form | NO: Normally Open, NC: Normally Closed |
| Control output | Load current below 200mA (residual constant voltage below 1V) |
| Display lamp | Action indicator light (red) |
| Protection circuit | Surge protection circuit, short circuit protection, reverse polarity protection |
| Ambient temperature | Operating temperature: -25 to 70℃ (no freezing, no condensation) |
| Ambient humidity | During operation and storage: 35-95% RH (non-condensing) |
| The effect of temperature | Temperature range -25-70℃, with a detection distance change within ±10% for every 20℃ change. |
| Effect of voltage | When the rated power supply voltage fluctuates within ±15%, the detection distance changes within ±1%. |
| Insulation resistance | 50MΩ or higher (DC 500 megohm meter) between the charging section and the casing |
| Withstand voltage | AC1000V 50/60Hz 1min charging unit and casing |
| Vibration resistance | 10~55Hz, amplitude 1.5mm, 2h in each of the X, Y, and Z directions. |
| Impact resistance | 500m/SX, Y, Z 10 times each |
| Connection method | Lead-out type (standard lead wire length 2m), special (PUR customizable) drag chain cable |
| Shell material | Nickel-plated copper material |
| Protection level | Ip67 |
▶ Product Specifications - M12/M18
| kinds | M12 Qi Ping | M12⾮Qiping | M18 Qi Ping | M18⾮Qiping |
|---|---|---|---|---|
| Model (NPN) | HT-1202-E1 (Normally Open) | HX-1204-E1 (Normally Open) | HT-1805-E1 (Normally Open) | HX-1808-E1 (Normally Open) |
| Model (NPN) | HT-1202-E2 (Normally Closed) | HX-1204-E2 (Normally Closed) | HT-1805-E2 (Normally Closed) | HX-1808-E2 (Normally Closed) |
| Model (PNP) | HT-1202-P1 (Normally Open) | HX-1204-P1 (Normally Open) | HT-1805-P1 (Normally Open) | HX-1808-P1 (Normally Open) |
| Model (PNP) | HT-1202-P2 (Normally Closed) | HX-1204-P2 (Normally Closed) | HT-1805-P2 (Normally Closed) | HX-1808-P2 (Normally Closed) |
| Detection distance | 2mm±10% | 4mm±10% | 5mm±10% | 8mm±10% |
| Standard test object (iron) | 12x12x1mm | 12x12x1mm | 18x18x1mm | 18x18x1mm |
| Set distance | 0-1.6mm | 0-3.2mm | 0-4mm | 0-6.4mm |
| Response frequency | 1000HZ | 800HZ | 500HZ | 400HZ |
| wire diameter | 3.8mm | 3.8mm | 4.8mm | 4.8mm |
▶ Main parameters - M30 / Plugin M12
| Detecting objects | Magnetic metals |
|---|---|
| Difference distance | less than 10% of the detection distance |
| power supply voltage | DC12-24V ripple (pp) below 10% (DC10-30V) |
| Leakage current | Below 0.05mA |
| Action Form | NO: Normally Open, NC: Normally Closed |
| Control output | Load current below 200mA (residual constant voltage below 1V) |
| Display lamp | Action indicator light (red) |
| Protection circuit | Surge protection circuit, short circuit protection, reverse polarity protection |
| Ambient temperature | Operating temperature: -25 to 70℃ (no freezing, no condensation) |
| Ambient humidity | During operation and storage: 35-95% RH (non-condensing) |
| The effect of temperature | Temperature range -25-70℃, with a detection distance change within ±10% for every 20℃ change. |
| Effect of voltage | When the rated power supply voltage fluctuates within ±15%, the detection distance changes within ±1%. |
| Insulation resistance | 50MΩ or higher (DC 500 megohm meter) between the charging section and the casing |
| Withstand voltage | AC1000V 50/60Hz 1min charging unit and casing |
| Vibration resistance | 10~55Hz, amplitude 1.5mm, 2h in each of the X, Y, and Z directions. |
| Impact resistance | 500m/SX, Y, Z 10 times each |
| Connection method | The plug-in program comes with a dedicated 2-meter connection cable. |
| Shell material | Nickel-plated copper material |
| Protection level | Ip67 |
▶ Product Specifications - M30 / Plugin M12
| kinds | M30 Qi Ping | M30⾮Qiping | M12 plug-in version | External program version M12⾮Flat |
|---|---|---|---|---|
| Model (NPN) | HT-3010-E1 (Normally Open) | HX-3015-E1 (Normally Open) | HT-1202-E1C (Normally Open) | HX-1204-E1C (Normally Open) |
| Model (NPN) | HT-3010-E2 (Normally Closed) | HX-3015-E2 (Normally Closed) | HT-1202-E2C (Normally Closed) | HX-1204-E2C (Normally Closed) |
| Model (PNP) | HT-3010-P1 (Normally Open) | HX-3015-P1 (Normally Open) | HT-1202-P1C (Normally Open) | HX-1204-P1C (Normally Open) |
| Model (PNP) | HT-3010-P2 (Normally Closed) | HX-3015-P2 (Normally Closed) | HT-1202-P2C (Normally Closed) | HX-1204-P2C (Normally Closed) |
| Detection distance | 10mm±10% | 15mm±10% | 2mm±10% | 4mm±10% |
| Standard test object (iron) | 30x30x1mm | 30x30x1mm | 12x12x1mm | 12x12x1mm |
| Set distance | 0-8mm | 0-12mm | 0-1.6mm | 0-3.2mm |
| Response frequency | 300HZ | 200HZ | 800HZ | 600HZ |
| wire diameter | 4.8mm | 4.8mm | - | - |
▶ Main parameters - Plugin M18 / Plugin M30
| Detecting objects | Magnetic metals |
|---|---|
| Difference distance | less than 10% of the detection distance |
| power supply voltage | DC12-24V ripple (pp) below 10% (DC10-30V) |
| Leakage current | Below 0.05mA |
| Action Form | NO: Normally Open, NC: Normally Closed |
| Control output | Load current below 200mA (residual constant voltage below 1V) |
| Display lamp | Action indicator light (red) |
| Protection circuit | Surge protection circuit, short circuit protection, reverse polarity protection |
| Ambient temperature | Operating temperature: -25 to 70℃ (no freezing, no condensation) |
| Ambient humidity | During operation and storage: 35-95% RH (non-condensing) |
| The effect of temperature | Temperature range -25-70℃, with a detection distance change within ±10% for every 20℃ change. |
| Effect of voltage | When the rated power supply voltage fluctuates within ±15%, the detection distance changes within ±1%. |
| Insulation resistance | 50MΩ or higher (DC 500 megohm meter) between the charging section and the casing |
| Withstand voltage | AC1000V 50/60Hz 1min charging unit and casing |
| Vibration resistance | 10~55Hz, amplitude 1.5mm, 2h in each of the X, Y, and Z directions. |
| Impact resistance | 500m/SX, Y, Z 10 times each |
| Connection method | The plug-in program comes with a dedicated 2-meter connection cable. |
| Shell material | Nickel-plated copper material |
| Protection level | Ip67 |
▶ Product Specifications - Plugin M18 / Plugin M30
| kinds | M18 plug-in version | External program version M18⾮ flat | The plug-in version of the M30 is flush with the screen. | External program version M30 ⾮ level |
|---|---|---|---|---|
| Model (NPN) | HT-1805-E1C (Normally Open) | HX-1808-E1C (Normally Open) | HT-3010-E1C (Normally Open) | HX-3015-E1C (Normally Open) |
| Model (NPN) | HT-1805-E2C (Normally Closed) | HX-1808-E2C (Normally Closed) | HT-3010-E2C (Normally Closed) | HX-3015-E2C (Normally Closed) |
| Model (PNP) | HT-1805-P1C (Normally Open) | HX-1808-P1C (Normally Open) | HT-3010-P1C (Normally Open) | HX-3015-P1C (Normally Open) |
| Model (PNP) | HT-1805-P2C (Normally Closed) | HX-1808-P2C (Normally Closed) | HT-3010-P2C (Normally Closed) | HX-3015-P2C (Normally Closed) |
| Detection distance | 5mm±10% | 8mm±10% | 10mm±10% | 15mm±10% |
| Standard test object (iron) | 18x18x1mm | 18x18x1mm | 30x30x1mm | 30x30x1mm |
| Set distance | 0-4mm | 0-6.4mm | 0-8.0mm | 0-12mm |
| Response frequency | 600HZ | 400HZ | 350HZ | 300HZ |